TRICOR Systems Inc. has provided electronic contract manufacturing since 1976. TRICOR’s award winning engineering staff develops electro-mechanical/electro-optical equipment from concept to finished product. TRICOR designs and manufactures Class 1, 2 & 3 medical devices and offers services... Read More
F2 Labs is an accredited, full-service product conformity assessment organization. Our facilities are ISO/IEC 17025 accredited by the American Association of Laboratory Accreditation (A2LA). Our safety test reports and evaluations are accepted by an OSHA accredited NRTL. We are also recognized... Read More
PSN Labs is an engineering services firm offering customized solutions in all areas and stages of medical device development. With three internal labs - design engineering; prototyping and molding; and material/product testing - we can solve the toughest challenges of development at any phase.... Read More
Chroma Systems Solutions is a single source solution and preferred instrument and systems supplier to IT, network, computing and data center product manufacturers. Chroma’s test instruments and systems are used to help achieve power efficiency requirements for global markets including ENERGY... Read more »
Besides testing capacitors, inductors and resistors individually, the passive component test devices are also able to measure assorted electronic components composed of them. Individual components include wound components and communication and power filters; Composites include switches,... Read more »
Hipot testing or dielectric strength testing determines the suitability of the dielectric or insulation barrier between hazardous and non-hazardous parts. The IEC60601-1 standard and its supporting standards specify the voltage to be applied to the device under test (DUT) and the acceptance... Read more »
By Chroma Systems Solutions
Leakage current testing is the measurement of electrical “leakage current” that results from powering
an electrical appliance via mains or dc power. Leakage current is the unwanted or unintended flow of
electrical current that presents an electrical hazard such as shock or burn.
Read More
By Chroma Systems Solutions
The 19032 Series Electrical Safety Analyzer can be used with external 5000-03 Scanners to accomplish
testing on Class II medical appliances per IEC 60601-1. Tests include Enclosure Leakage, Patient Leakage, Patient Aux Leakage, Mains to Enclosure Hipot, Mains to AP Hipot, and AP to Enclosure...
Read More
By Chroma Systems Solutions
The 19032 series can be used with an external 5000-03 Scanner to accomplish testing on Class I medical
devices per IEC 60601-1. Tests include: Earth Line Leakage, Patient Leakage, Mains to Enclosure Hipot,
AP to Protective Earth PE Hipot and F-Type Mains to AP. The external scanner is used to...
Read More